Ozone Test Strips

Ozone Test Strips provide a quick indication of ambient levels of ozone in both indoor and outdoor air. Because high concentrations of ozone have been medically proven to damage lung tissue and reduce lung efficiency by up to 20%, it is important to monitor ozone levels within an area.

Ozone Test Strips

  • Simple to use
  • Chemically treated to react with ozone
  • Easy to read colour reaction

Simply place in the area to be tested. After 10 minutes the test strip is compared with the colour scale on the test strip package. The strip will produce a result as a colour change in four distinct colours, from light yellow to dark yellow. Each colour represents a specified level of ozone concentration ranging from <0.045 ppm to >0.105 ppm (<45 ppb to >105 ppb), as below:

Indication Ozone Concentration
A < 0.045 ppm (45 ppb)
B 0.045 ppm to 0.075 ppm (45 to 75 ppb)
C 0.075 ppm to 0.105 ppm (75 to 105 ppb)
D > 0.105 ppm (105 ppb)

Note: For use in environments with Relative Humidity between 30 and 60%RH.

Description Pack Size Part Number
Ozone Test Strips 50 526-300

Passive Sampler Selection GuidePassive Sampler Selection Guide
Hazard SearchHazard Search
What is Air Sampling?What is Air Sampling?
ContactContact

Elemental Mercury Passive Sampler

The SKC 520 Series Elemental Mercury Sampler measures worker exposure levels as a Time-Weighted Average (TWA) and permits the positive analysis of elemental mercury vapour. It is designed for analysis using standard laboratory equipment, and therefore, the cost per measurement is kept to an absolute minimum compared to other samplers. The sampler only samples elementary mercury (Hg) in the vapour phase; it does not sample elemental Hg in the particulate phase or organic mercury compounds.

Mercury vapour enters the sampler by positive, controlled diffusion so that a known sample volume is taken for a given period of time. Mercury is completely adsorbed onto the solid sorbent. The sorbent capsule is then taken to an accredited laboratory where the sorbent is dissolved in acid and analyzed by flameless atomic absorption. The sampler holder is cleaned and reused, thereby reducing sampling costs.

Elemental Mercury Passive Sampler

  •  
  • Extensively field tested
    • Validation based on OSHA Method ID-140
    • Meets NIOSH and OSHA standards
  • Lowest cost per measurement available
    • Reusable capsule holder
    • Replaceable sorbent capsule
  • Easy-to-use
    • Clips to a worker’s collar or pocket
    • No pump needed
  • Long-term sampling up to 120 hours
  • High accuracy and sensitivity
    • Positive analysis of inorganic mercury
    • Removable sorbent capsule eliminates false high readings due to contamination of badge housing
  • No moisture or chlorine interferences
    • Extensive field testing and chamber studies show accuracy without interference from either moisture or chlorine
  • Simple analysis
    • Uses standard laboratory equipment and analytical methods

Note: For sampling low levels of mercury, use a sorbent tube.

Passive Sampler Selection GuidePassive Sampler Selection Guide
Hazard SearchHazard Search
What is Air Sampling?What is Air Sampling?
ContactContact

UMEx 100 Passive Sampler for Formaldehyde

The UMEx 100 Passive Sampler for formaldehyde was developed in collaboration with the National Institute of Working Life in Umea, Sweden.

Constructed of tough polypropylene, the single-use UMEx 100 contains a tape treated with 2,4-dinitrophenylhydrazine (DNPH) for reliable collection of formaldehyde. Samplers are provided in individual aluminiumised pouches that can be used to transport the sampler to a laboratory after sampling.

For convenience and quality control assurance against contamination, each sampler incorporates a "blank/correction" section in addition to the active sampling section so there is no need to send extra samplers to the laboratory.

The shelf-life date is printed on a label on the outside of each pouch for easy inventory management. The UMEx 100 Sampler includes a clip for attachment to a worker’s collar for personal sampling or in an appropriate location for area sampling.

UMEx 100 Formaldehyde Passive Sampler
  •  
  • Accurate and reliable for formaldehyde collection
  • Accuracy exceeds OSHA standards
  • Uses popular 2,4-DNPH chemistry
  • Validated by OSHA and Swedish Institute
  • Economical low cost sampler
  • Easy to use - no pump or training required
  • Sample medium and blank/correction in one unit
  • Conforms to EU ISO 16000-4-2004
  • Documented uptake rates
    • For 15 minute to 24 hour samples
    • For 7 day samples*  
  • Meets specifications of OSHA Method 1007  
  • Referenced in EPA IP-6C
  • Highly sensitive and specific analysis method
  • Small and unobtrusive
  • Simple-to-use "on/off" sliding cover
  • Low 2 ppb limit of detection
  • Safe - No glass or chemical liquids in the sampler
  • 28.6 ml/min uptake rate enhances sensitivity for 15 minute, 8 hour, and 24 hour sampling*  
  • Versatile sampler - suitable for both workplace sampling and long term indoor air sampling

Note: If sampling in an atmosphere where Formalin is the source of Formaldehyde, please see the Technical Note under Documentation.

Passive Sampler Selection GuidePassive Sampler Selection Guide
Hazard SearchHazard Search
What is Air Sampling?What is Air Sampling?
ContactContact

ULTRA Passive Samplers

The ULTRA Passive Samplers from SKC are the creative evolution of indoor and ambient air sampling. The patented* ULTRA samples by diffusion and provides low ppb to ppt detection of compounds, including semi-volatile organic compounds (SVOCs). Operation is as easy as sliding the cover open to start sampling and closing it to stop sampling.

ULTRA Passive Sampler
ULTRA Passive Sampler - rear view
  •  
  • Provides results comparable to canisters for EPA Method TO-15
    • No cleaning or certification costs
    • Lower purchase price
    • No expensive shipping
  • Passive alternative for EPA Method TO-17 — no pump required
  • Choice of 5 sorbents for indoor and ambient air sampling, including semi-volatile organic compounds (SVOCs):
    • Anasorb GCB1
    • Tenax TA
    • Chromosorb 106
    • Anasorb CSC (solvent desorption)
    • Carbopack X
  • Slide cover for easy on/off
  • Miniature lightweight sampler is easy to transport — no expensive shipping
  • Validated sampling (uptake) rates
  • Built-in blank/correction sorbent section (Also available with sorbent loaded in the sample compartment only, when a blank is not required)
  • Also available as an empty housing with separate sorbent vials for user-filled samplers.
  • Sample integrity:
    • Sonically welded housing seals the sampler
    • Manufactured in an ultra-clean environment
    • Extensive cleaning and quality control procedures
  • Long term sampling up to 30 days reduces temporal variability. Please contact SKC for details.
  • Allows rapid deployment of multiple samplers for emergency stations
  • Easy operation for community action programmes

* US Patent No. 6,607,581

Applications

  • Public health/asthma studies
  • Near roadway air quality studies
  • Volatiles from soil gas, biological sources, and water
  • Traffic studies
  • Fenceline monitoring
  • Monitoring pollution migration from industrial processes
  • Odour profiling in fragrance, food, and flavour industries
  • Product emissions
  • Emergency response to oil spills and leaks
  • Green Building certification
  • Vapour intrusion
  • School zone studies

Passive Sampler Selection GuidePassive Sampler Selection Guide
Hazard SearchHazard Search
What is Air Sampling?What is Air Sampling?
ContactContact

UMEx 200 Passive Sampler for SO2/NO2

The lightweight UMEx 200 clips in the breathing zone for easy personal sampling. The sample medium (tape treated with triethanolamine [TEA]) and a "blank/correction" section of tape are contained in one sampler saving time and money. Samplers are provided in individual aluminiumised pouches that can be used to transport the sampler to a laboratory. The label on the outside of each pouch contains the shelf-life date for easy inventory management.

UMEx 200 SO2/NO2 Passive Sampler
  •  
  • Same chemistry as active OSHA Method ID-182
  • Ready to use
  • Accurate, reliable personal sampling
  • Lightweight sampler clips easily in the breathing zone
  • Economical , low cost, single use sampler
  • Safe — no glass or chemical liquids in the sampler
  • No pump or training required
  • Sample medium and blank/correction in one unit
  • Accurately measures personal workplace exposure to sulphur dioxide and/or nitrogen dioxide from 15 minutes to 8 hours (Not suitable for new STEL of 0.25 ppm)
  • 3-week sample storage at ambient temperature

SKC Research has validated the UMEx 200 Passive Sampler for 24 hour ambient air sampling of sulphur dioxide and nitrogen dioxide to complement federal EPA reference methods. The validated concentration range for sulphur dioxide is 0.4 to 8 ppm (15 minutes to 24 hours); nitrogen dioxide is 0.05 to 8 ppm (15 minutes to 24 hours).

Sulphur dioxide is used in:

  • Intermediate in the manufacture of sulphuric acid
  • Bleaching agent
  • Disinfectant
  • Fumigant
  • Solvent
  • Refrigerant
  • Food preservative
  • Reagent in the manufacture of magnesium, sodium sulphite and other chemicals

Nitrogen dioxide is used in:

  • Agricultural silos
  • Arc or gas welding, especially in confined space
  • Electroplating plants
  • Food and textile bleaching
  • Jewelery manufacturing
  • Nitric acid production
  • Nitrogen fertiliser production
  • Nitro-explosive production
  • Pickling plants

Passive Sampler Selection GuidePassive Sampler Selection Guide
Hazard SearchHazard Search
What is Air Sampling?What is Air Sampling?
ContactContact

Save
Cookies user preferences
We use cookies to ensure you to get the best experience on our website. If you decline the use of cookies, this website may not function as expected.
Accept all
Decline all
Read more
Analytics
Tools used to analyze the data to measure the effectiveness of a website and to understand how it works.
Google Analytics
Accept
Decline