Skip to main content

Sioutas Personal Cascade Impactor

The Sioutas Personal Cascade Impactor separates and collects airborne particles in five size ranges. When used with PTFE filters the Sioutas Impactor is highly efficient at collecting particles without the use of impaction grease or substrate coatings, and at retaining unstable compounds for size-fractionated chemical analysis. It is the only personal impactor that efficiently samples coarse, fine and ultrafine particles simultaneously. Particles above each cut-point are collected on 25 mm filter in the appropriate stage with particles below 0.25 µm collecting on the 37 mm after-filter (optional). Use the Sioutas Impactor with the Leland Legacy sample pump at 9 L/min to ensure precise particle separation at the specified cut-points.

Sioutas Personal Cascade Impactor
  • Precise particle separation
    • Particle size cut-points: 2.5 µm, 1.0 µm, 0.5 µm and 0.25 µm
    • Maintains high collection efficiency even at high particle concentrations
  • Optimised at a 9 L/min flow rate with low pressure drop for 24 hour sampling
    • Improves analytical sensitivity
    • Minimises non-detectable samples
  • Preserves unstable compounds
    • Chemically inert collection substrate
    • No impaction grease to contaminate sample
  • Minimal particle bounce and internal wall losses
  • Suitable for indoor and outdoor sampling *  

* Requires special provisions, please see the Sioutas Cascade Impactor Instructions.

Filters for the Sioutas Impactor

The Sioutas Impactor uses four 25 mm filters (required) and one 37 mm filter (optional). The 25 mm PTFE filters act as a collection substrate and the optional 37 mm PTFE filter is the final collection filter (After-filter). We recommend PTFE filters to minimise particle bounce and to preserve unstable compounds. Coated collection substrate may be used if desired. However, a coating is not necessary and can interfere with chemical analysis.

Applications
  • Occupational hygiene studies
  • Indoor Air Quality (IAQ) studies
  • Air pollution studies
  • Inhalation toxicology and epidemiological studies
  • Aerosol research
  • Pharmaceutical studies
  • Outdoor ambient sampling *  

* Requires special provisions, please see the Sioutas Cascade Impactor Instructions.

Specifications
Flow Rate    9 L/min
50% Cut-point    Stage A: 2.5 µm
Stage B: 1.0 µm
Stage C: 0.50 µm
Stage D: 0.25 µm
Material    Anodised aluminium
O-rings: BUNA-N
Filter retainers: Acrylic
Maximum Operating Temperature    PTFE Filters with PMP support ring is 240°C (464°F)
Recommended After-filter    37 mm 2.0 µm PTFE with PMP support ring (Part no. 225-1709)
Recommended Collection filter for Stages    25 mm 0.5 µm PTFE with laminated PTFE support (Part no. 225-17-21)
Tubing    3/8 inch (9.53mm) ID
Outlet Diameters    Inlet: 3/8 in OD and 1/4 in ID
Outlet: 3/8 in OD and 1/4 in ID
Dimensions    8.6 x 5.5 cm (3.4 x 2.2 in)
Weight    159g (5.6 oz)
Sioutas Personal Cascade Impactor
Description Pack Size Part Number
Sioutas Personal Cascade Impactor Each 225-370
Accessories
Description Pack Size Part Number Part Number
Replacement Collector Plates, set of 4 Each P55016 no image
Retainer Rings only 4 P20151 no image
Replacement O-ring, Retainer, and Spacer Set for Sioutas Impactor includes 4 filter retainer rings, 9 O-rings, and 1 PTFE spacer ring Each P51917 no image
After-filter, 37 mm PTFE      , 2.0 µm, optional 50 225-1709  225-1709 PTFE After-filter, diameter 37 mm, pore size 2.0 µm 
Collection Substrate (filter for 4 stages), 25 mm, PTFE    , 25 mm, 0.5 µm pore, required 100 225-17-21  225-3708 Collection Substrate (PTFE filter for 4 stages), diameter 25 mm, pore size 0.5 µm 

  Back pressure on PTFE filters can vary within the same lot.
  The maximum operating temperature for PTFE filters with PMP support ring is 240°C (464°F).

Replacement Collector Plates, set of 4

P55016

Retainer Rings only

P20151

Replacement O-ring, Retainer, and Spacer Set, includes 4 filter retainer rings, 9 O-rings, and 1 PTFE spacer ring

P51917

After-filter, 37 mm PTFE, 2.0 µm (optional)

225-1709

Collection Substrate (filter for 4 stages), 25 mm, PTFE †  , 25 mm, 0.5 µm pore (required)

225-17-21

Sioutas Breakdown

Sioutas Breakdown

Sioutas Outlet Plate Breakdown

Sioutas Outlet Plate Breakdown

Sioutas Filters & Filter Retainers

Sioutas Filters & Filter Retainers

Documentation
Sioutas  Cascade Impactor Instructions

Sioutas Cascade Impactor
Instructions