Skip to main content

ULTRA Passive Samplers

The ULTRA Passive Samplers from SKC are the creative evolution of indoor and ambient air sampling. The patented* ULTRA samples by diffusion and provides low ppb to ppt detection of compounds, including semi-volatile organic compounds (SVOCs). Operation is as easy as sliding the cover open to start sampling and closing it to stop sampling.

ULTRA Passive Sampler
ULTRA Passive Sampler - rear view
    • Provides results comparable to canisters for EPA Method TO-15
    • No cleaning or certification costs
    • Lower purchase price
    • No expensive shipping
  • Passive alternative for EPA Method TO-17 — no pump required
  • Choice of 5 sorbents for indoor and ambient air sampling, including semi-volatile organic compounds (SVOCs):
    • Anasorb GCB1
    • Tenax TA
    • Chromosorb 106
    • Anasorb CSC (solvent desorption)
    • Carbopack X
  • Slide cover for easy on/off
  • Miniature lightweight sampler is easy to transport — no expensive shipping
  • Validated sampling (uptake) rates
  • Built-in blank/correction sorbent section (Also available with sorbent loaded in the sample compartment only, when a blank is not required)
  • Also available as an empty housing with separate sorbent vials for user-filled samplers.
  • Sample integrity:
    • Sonically welded housing seals the sampler
    • Manufactured in an ultra-clean environment
    • Extensive cleaning and quality control procedures
  • Long term sampling up to 30 days reduces temporal variability. Please contact SKC for details.
  • Allows rapid deployment of multiple samplers for emergency stations
  • Easy operation for community action programmes

* US Patent No. 6,607,581

Applications
  • Public health/asthma studies
  • Near roadway air quality studies
  • Volatiles from soil gas, biological sources, and water
  • Traffic studies
  • Fenceline monitoring
  • Monitoring pollution migration from industrial processes
  • Odour profiling in fragrance, food, and flavour industries
  • Product emissions
  • Emergency response to oil spills and leaks
  • Green Building certification
  • Vapour intrusion
  • School zone studies
Pre-filled ULTRA Samplers with built-in blank (including instructions)
Description Pack Size Part Number
ULTRA Passive Samplers Prefilled with Sorbent - Anasorb GCB1 # , 370 mg in each compartment. Comparable to Carbopack B. 5 690-101
ULTRA Passive Samplers Prefilled with Sorbent - Chromosorb 106 # , 285 mg in each compartment
Go to www.osha.gov and search on ULTRA for additional information on sampling rates for Chromosorb 106.
5 690-103
ULTRA Passive Samplers Prefilled with Sorbent - Tenax TA # , 265 mg in each compartment. 5 690-104
ULTRA Passive Samplers Prefilled with Sorbent - Anasorb CSC # , 500 mg in each compartment. 5 690-105
ULTRA Passive Samplers Prefilled with Sorbent - Carbopack X # , 400 mg in each compartment. 5 690-106

Table Notes:

# Limited shelf-life

ULTRA III 690-101/103/104/106 Instructions   ULTRA III 690-105 Passive Sampler Instructions

ULTRA 690-101/103/104/106
Instructions

 

ULTRA 690-105
Instructions

Pre-filled ULTRA Samplers without built-in blank (including instructions)
Description Pack Size Part Number
ULTRA Passive Samplers - Anasorb GCB1 #  without blank sorbent. 5 690-101-NB
ULTRA Passive Samplers Prefilled with Sorbent - Chromosorb 106 # , without blank sorbent.
Go to www.osha.gov and search on ULTRA for additional information on sampling rates for Chromosorb 106.
5 690-103-NB
ULTRA Passive Samplers Prefilled with Sorbent - Tenax TA # , without blank sorbent. 5 690-104-NB
ULTRA Passive Samplers Prefilled with Sorbent - Anasorb CSC # , without blank sorbent. 5 690-105-NB
ULTRA Passive Samplers Prefilled with Sorbent - Carbopack X # , without blank sorbent. 5 690-106-NB

Table Notes:

# Limited shelf-life

ULTRA III 690-101/103/104/106NB Passive Sampler Instructions   ULTRA III 690-105NB Passive Sampler Instructions

ULTRA 690-101NB/103NB/104NB/
106NB Instructions

 

ULTRA 690-105NB
Instructions

Sorbent Vials for User-filled ULTRA Samplers (including instructions)
Description Pack Size Part Number  
ULTRA Passive Sampler Empty Housing, User fillable. Requires Sorbent Vial for operation Each 690-200   690-200 ULTRA Passive Sampler Empty Housing, User fillable 
ULTRA Sorbent Vials Anasorb GCB1, 370 mg in each vial 2 690-201   690-201 ULTRA Sorbent Vials Anasorb GCB1, 370 mg in each vial 
ULTRA Sorbent Vials Chromosorb 106, 285 mg in each vial 2 690-203   690-203 ULTRA Sorbent Vials Chromosorb 106, 285 mg in each vial 
ULTRA Sorbent Vials Tenax TA, 265 mg in each vial 2 690-204   690-204 ULTRA Sorbent Vials Tenax TA, 265 mg in each vial 
ULTRA Sorbent Vials Anasorb CSC, 500 mg in each vial 2 690-205   690-205 ULTRA Sorbent Vials Anasorb CSC, 500 mg in each vial 
ULTRA Sorbent Vials Carbopack X, 400 mg in each vial 2 690-206   690-206 ULTRA Sorbent Vials Carbopack X, 400 mg in each vial 
ULTRA Transfer Funnel, for transferring sorbent from sorbent vials into empty ULTRA Passive Sampler housing Each 690-301   690-301 ULTRA Transfer Funnel, for transferring sorbent from sorbent vials into empty ULTRA Passive Sampler housing 
ULTRA Passive Sampler Empty Housing, User fillable. Requires Sorbent Vial for operation

690-200

Anasorb GCB1 Sorbent Vial

690-201

Chromosorb 106 GCB1 Sorbent Vial

690-203

Tenax TA Sorbent Vial

690-204

Charcoal Sorbent Vial

690-205

ULTRA Sorbent Vials Carbopack X, 400 mg in each vial

690-206

ULTRA Transfer Funnel

690-301

ULTRA 690-200 Sampler Instructions

ULTRA 690-200 User-Filled
Badge Instructions

ULTRA Accessories
Description Pack Size Part Number  
Stand for Indoor Sampling Each 690-302   690-302 Stand for mounting passive samplers for Indoor Sampling 
Shelter for Outdoor Sampling Each 690-303   690-303 Shelter for mounting passive samplers for Outdoor Sampling 
ULTRA Transfer Funnel, for transferring sorbent from sorbent vials into empty ULTRA Passive Sampler housing Each 690-301   690-301 ULTRA Transfer Funnel, for transferring sorbent from sorbent vials into empty ULTRA Passive Sampler housing 
Thermal Desorption Tube, Perkin Elmer, 6.35 x 90 mm (0.25 x 3.5 inches), includes screens and end caps Each P226530 no image
Analysis Transfer Funnel, facilitates transfer of sorbent from vial to 6.35 mm (0.25 inch) OD thermal desorption tubes (P226530) Each 590-264   590-264 Analysis Transfer Funnel, facilitates transfer of sorbent from vial to 6.35 mm (0.25 inch) OD thermal desorption tubes (P226530) 
Stand for Indoor Sampling

690-302

Shelter for Outdoor Sampling

690-303

ULTRA Transfer Funnel, for transferring sorbent from sorbent vials into empty ULTRA Passive Sampler housing

690-301

Analysis Transfer Funnel, facilitates transfer of sorbent from vial to 6.35 mm (0.25 inch) OD thermal desorption tubes (P226530)

590-264

Thermal Desorption Tube, Perkin Elmer, 6.35 x 90 mm (0.25 x 3.5 inches), includes screens and end caps

P226530

ULTRA Sampler Selection Guide
ULTRA Passive Sampler Selection Guide

ULTRA Sampler Selection Guide