Skip to main content

HAZ-SCANNER IEMS Indoor Environmental Monitoring Station - DISCONTINUED

The HAZ-SCANNER™ IEMS portable, indoor environmental air monitoring station can be configured for up to 14 simultaneous air measurements including standard configuration of PM10 or TSP, CO2, CO, temperature, and relative humidity. Use the IEMS for air profiles at schools, LEED green building certification, job task analysis, and IEQ assessments.

HAZ-SCANNER IEMS
HAZ-SCANNER IEMS Rear
HAZCOMM Software

  • Direct reading
  • Measures and displays data for up to 14 critical indoor air quality parameters
    • Standard IEMS configuration: measure 5 parameters including PM10 or TSP particulates, CO2, CO, temperature, and relative humidity
    • Optional: Add up to 9 optional interchangeable sensors and/or IEMS-specific meters (up to 9 sensors/meters total)
      Choose from additional toxic gas sensors, PID for VOCs, or IEMS-specific meters for light intensity, sound/noise, atomic/nuclear radiation, ELF radiation, and air velocity
    • Available analogue input port for alternative meter
  • Interchangeable size-selective impactors are available for PM1.0, PM2.5, or PM4.0 (close approximation of respirable)
  • In-line standard 37 mm or optional 25 mm gravimetric filter cassette provides concurrent filter sampling for chemical and biological analyses
  • Internal sample pump provides flow rate of 2 L/min
  • NiMH battery for 8-hour operation, continuous operation with AC power
  • Displays TWA, STEL, Max, and Min
  • Optional alarm indicator light and siren for user-defined threshold limits
  • Removable handheld sensors for spot-checking remote areas
  • Datalogging and optional real-time wireless data transmission
  • Easy-to-use graph and reporting software — compatible with PC and Mac

Specifications

Display    LCD
Operation    4 key splashproof membrane switch
Power    12V NiMH rechargeable battery
Operating Time    8 hours on battery, continuous on AC
Display Measurements    TWA, STEL, Max, Min
Recording Time    1 second to 50 weeks
Sampling Rate    1 second, 1 minute, 10 minute intervals
Data Storage    454,545 data points
Sampling Pump    2 L/min
Digital Output    RS232 (PC), RS423 (Mac)
Software    PC or Mac compatible
Dimensions    17.8 x 10.2 x 28 cm (7 x 4 x 11 in)
Weight    2700 g (6 lbs)
Operating Temperature    -5 to 50°C (23 to 122°F)
Storage Temperature    -20 to 60°C (-4 to 140°F)
Humidity    95%, non-condensing
Auxiliary Analogue Output    0 to 2.5V DC ( channel for alternative meter)

HAZ-SCANNER IEMS

Description Part Number
HAZ-SCANNER IEMS Standard Configuration, includes:

particulate sensor for TSP, impactor for PM10 sampling, CO2, CO, temperature, and relative humidity sensors, NiMH battery and charger, HazComm Pro Software and Instructions on USB Memory Stick, cables and carry case

770-800

IEMS-specific Optional Meters (up to 5)

Each meter includes a holder to mount the meter on the tripod accessory.

Description Part Number  
Air Velocity Meter, 80 to 5910 ft/min 770-801 no image
Atomic/Nuclear Radiation Meter, 1 to 19,999 cpm or 0.001 or 100 mR/hr 770-802  770-802 Atomic/Nuclear Radiation Meter, 1 to 19,999 cpm or 0.001 or 100 mR/hr for HAZ-SCANNER IEMS 
ELF (Extremely Low Frequency) Gauss Radiation Meter, 1 to 200 G 770-803 no image
Indoor Light Intensity Meter, 0 to 50,000 lux/0 to 5000 fc 770-804  770-804 Indoor Light Intensity Meter, 0 to 50,000 lux/0 to 5000 fc for HAZ-SCANNER IEMS 

IEMS-specific Optional Sensors (up to 4)

Each meter includes a holder to mount the meter on the tripod accessory.

Description Part Number  
Nitrogen Dioxide Sensor, 0 to 20 ppm 770-805  770-805 Nitrogen Dioxide Sensor, 0 to 20 ppm for HAZ-SCANNER IEMS 
Sulphur Dioxide Sensor, 0 to 20 ppm 770-806  770-806 Sulphur Dioxide Sensor, 0 to 20 ppm for HAZ-SCANNER IEMS 
Oxygen Sensor, 0 to 30 %vol 770-807  770-807 Oxygen Sensor, 0 to 30 %vol for HAZ-SCANNER IEMS 
Ozone Sensor, 0 to 0.5 ppm 770-808  770-808 Ozone Sensor, 0 to 0.5 ppm for HAZ-SCANNER IEMS 
Ozone Sensor, 0 to 5ppm 770-818  770-818 Ozone Sensor, 0 to 5ppm for HAZ-SCANNER IEMS 
PID for VOCs, 0 to 2000 ppm (isobutylene equivalent) 770-809 no image
Formaldehyde Sensor 770-819  770-819 Formaldehyde Sensor for HAZ-SCANNER IEMS 
Hydrogen Sulphide Sensor, 0-100 ppm 770-820  770-820 Hydrogen Sulphide Sensor, 0-100 ppm, for HAZ-SCANNER IEMS 

IEMS Accessories

Description Part Number  
Size-selective Impactor, PM1.0 770-811 no image
Size-selective Impactor, PM2.5 770-812 no image
Size-selective Impactor, PM4.0/respirable 770-813 no image
Size-selective Impactor, PM10 770-821 no image
Calibration Standard, particulate, for verifying span and optical sensor performance 770-207  770-207 Calibration Standard, particulate, for verifying span and optical sensor performance 
Tripod Stand, includes holder for IEMS, 1 to 1.5 m (3 to 5 ft) 770-814  770-814 Tripod Stand, includes holder for HAZ-SCANNER IEMS, 1 to 1.5 m (3 to 5 ft) 
External audible alarm 770-815 no image
Wireless Radio Modem, 900 MHz (US), 868MHz (Europe) with up to 450 m line-of-sight transmission 770-505X  770-505X Wireless Radio Modem, 900 MHz (US), 868MHz (Europe) with up to 450 m line-of-sight transmission 
Single AC Charger, 110-220V 770-825 no image
Replacement NiMH Battery Pack 770-810  770-810 Replacement NiMH Battery Pack for HAZ-SCANNER IEMS 
Calibration Gas Regulator, 1 L/min, for calibrating HAZ-SCANNER sensors 770-816  770-816 Calibration Gas Regulator, 1 L/min, for calibrating HAZ-SCANNER IEMS gas sensors 
Wireless Network Software for Windows and Apple Computers 770-507 no image

Documentation

IEMS Datasheet

HAZ-SCANNER IEMS
Datasheet

Particulate Sampler Selection GuideParticulate Sampler Selection Guide
Hazard SearchHazard Search
What is Air Sampling?What is Air Sampling?