Skip to main content

Personal Environmental Monitor (PEM)

The Personal Environmental Monitor (PEM) is a lightweight, personal sampling device used with a personal sampling pump to provide effective collection of particulates of either 2.5 (PM2.5) or 10 µm (PM10) aerodynamic equivalent diameter in indoor air. Personal exposure is determined through gravimetric analysis for particle mass and chemical analysis for specific compounds. The PEM is available in 3 different flow rates.

PEM for PM2.5 Flow 2 L/min
PEM for PM2.5 Flow 44 L/min
PEM for PM2.5 Flow 10 L/min
PEM for PM10 Flow 2 L/min
PEM for PM10 Flow 4 L/min
PEM for PM10 Flow 10 L/min
  • Small and unobtrusive - can be connected to a sample pump and worn in the breathing zone
  • Referenced in EPA Method IP-10A
  • Suitable for ACGIH thoracic TLVs, including sulphuric acid and cotton dust as thoracic particulate matter with 10 µm PEM

The PEM consists of 3 major parts: cap, impaction ring assembly, and base with after-filter. When used with a personal sampling pump at the required flow rate, the aerosol is accelerated through a number of nozzles in the cap. Through inertia, particles larger than 50% cut-point of the sampler impact onto a greased impaction ring and can be discarded after sampling. Particles smaller than the 50% cut-point pass through the impactor and collect on a 37 mm after-filter.

The PEM was developed for indoor air sampling. While it is not an EPA-certified instrument for ambient PM10 and PM2.5 sampling for the National Ambient Air Quality Standard (NAAQS), outdoor use can be effective if there is no excessive wind velocity or rain present at the time of sampling.

Specifications
Flow Rate    2,4 or 10 L/min
50% Cut-point    2.5 or 10 µm, depending on model
Sample Media    37 mm PTFE Filters
Tubing    3/16 inch (4.76mm) ID
Dimensions    60 x 65 x 22 mm (2.3 x 2.5 x 0.9 in)
Weight    48 g (1.7 oz)
Personal Environmental Monitors (PEMs)
Description Pack Size Part Number  
Personal Environmental Monitor (blue) for PM2.5 (2.5 µm)

Sampling Flow: 2 L/min
Each 761-203  761-203 Personal Environmental Monitor (PEM) (blue) for PM2.5 (2.5 µm), Sampling Flow: 2 L/min 
Personal Environmental Monitor (black) for PM2.5 (2.5 µm)

Sampling Flow: 4 L/min
Each 761-203A  761-203A Personal Environmental Monitor (PEM) (black) for PM2.5 (2.5 µm), Sampling Flow: 4 L/min 
Personal Environmental Monitor (red) for PM2.5 (2.5 µm)

Sampling Flow: 10 L/min
Each 761-203B  761-203B Personal Environmental Monitor (PEM) (red) for PM2.5 (2.5 µm), Sampling Flow: 10 L/min 
Personal Environmental Monitor (green) for PM10 (10 µm)

Sampling Flow: 2 L/min
Each 761-200  761-200 Personal Environmental Monitor (PEM) (green) for PM10 (10 µm), Sampling Flow: 2 L/min 
Personal Environmental Monitor (gold) for PM10 (10 µm)

Sampling Flow: 4 L/min
Each 761-200A  761-200A Personal Environmental Monitor (PEM) (gold) for PM10 (10 µm), Sampling Flow: 4 L/min 
Personal Environmental Monitor (bronze) for PM10 (10 µm)

Sampling Flow: 10 L/min
Each 761-200B  761-200B Personal Environmental Monitor (PEM) (bronze) for PM10 (10 µm), Sampling Flow: 10 L/min 
Accessories
Description Pack Size Part Number  
Calibration Cap Each 761-202  761-202 Calibration Cap for Personal Environmental Monitor (PEM) 
After-filter, 37 mm (2 µm pore PTFE     filter with PMP support ring) 50 225-1709  225-1709 PTFE After-filter, diameter 37 mm, pore size 2 µm pore for the Personal Environmental Monitor (PEM) 
Clamping Device, ensures that the nozzle cap is clamped parallel to the base Each 761-201 no image

Back pressure on PTFE filters can vary within the same lot.
The maximum operating temperature for PTFE filters with PMP support ring is 240°C.

PEM Calibration Adaptor

761-202

After-filter, 37 mm (2 µm pore PTFE filter with PMP support ring)

225-1709

Clamping Device, ensures that the nozzle cap is clamped parallel to the base

761-201

Documentation
Personal Environmental Monitor (PEM) Instructions

PEM
Instructions