Vac-U-Chamber

The SKC Vac-U-Chamber is a rigid air sample box that allows sample bags to be filled directly by using negative pressure provided by most personal air sample pumps. Because the sample does not pass through the pump, both pump and sample contamination are eliminated. All surfaces in contact with the sample are constructed of inert materials. The Vac-U-Chamber’s rigid walls will not collapse under vacuum conditions.

Slide 1
Slide 2
Slide 3
Slide 4

 

  • Allows direct filling of SKC air sample bags
    • Uses negative pressure provided by most personal air sample pumps
  • Protects sample pump from contamination
    • Sample does not pass through the pump
    • Sample contacts only inert tubing and bag
    • Sample line extends from contaminant source through case to bag
  • Rugged heavy-duty construction
    • Will not collapse under vacuum
    • Airtight
  • Four sizes available:
SizeSample Bag (L)Dimensions
Small 1 305 x 229 x 127 mm (12 x 9 x 5 inches)
Large 8 483 x 356 x 198 mm (19 x 14 x 7.8 inches)
Extra-Large 10 740 x 460 x 265 mm (29.1 x 18.1 x 10.4 inches)
Jumbo 25 784 x 660 x 394 mm (30.8 x 26 x 15.5 inches)

Applications:

  • Industrial VOCs
  • Indoor air quality
  • Effluent gas samples
  • Ground water testing
  • Stack sampling
  • Ventilation studies
  • Hazardous Material (HazMat) testing

Using the Vac-U-Chamber

The Vac-U-Chamber is equipped with three ¼ inch OD fitting ports for inflating sample bags:

  • Sample inlet port - for connecting to the sample line or gas source
  • Purge port - for purging the air prior to sampling or when preparing the bag for a standard
  • Vacuum port - for inflating a bag

An air sample bag is connected to the inside sample inlet port and the chamber is closed, providing an airtight seal. An air sample pump is connected to the outside vacuum outlet port. When activated, the pump evacuates air from inside the chamber. The sample bag inflates as a result of the interior pressure drop. This pneumatic technique allows the air sample to enter the bag directly without passing through the pump, protecting the pump from sample contaminants and the sample from pump contaminants.

Sample Bag Selection GuideSample Bag Selection Guide
Hazard SearchHazard Search
What is Air Sampling?What is Air Sampling?
ContactContact

Save
Cookies user preferences
We use cookies to ensure you to get the best experience on our website. If you decline the use of cookies, this website may not function as expected.
Accept all
Decline all
Read more
Analytics
Tools used to analyze the data to measure the effectiveness of a website and to understand how it works.
Google Analytics
Accept
Decline